Safety Precautions for Uninterruptible Power Supply (UPS) by Mohammad Umair Qureshi

Posted by Unknown on 12:30 AM

UPSToday. - This article for you with the title Safety Precautions for Uninterruptible Power Supply (UPS) that wrotted by Mohammad Umair Qureshi and published in articlesbase site on Dec 31, 2010. With this article we will know that safety roles, product safety, special precaution, installation and testing, location, protection, testing and activation, maintenance, normal operation, normal power loss, power restoration, by pass mode, and some note of Uninterruptible Power Supply (UPS).

Source: Screenshot of Gilbertconstruct

In this time we will republish again this article to you and you can give some comment or your opinion about this article in comment form that provide after this article you finished you read and understand.

Safety Rules

It is imperative that safety rules must be implemented prior installation of the UPS.The UPS must be installed in a space with restricted admittance (qualified personnel only). A UPS has its individual peripheral power source (the battery). Subsequently, the powers outlets may be energized even if the UPS is cut off from the AC-power source. Hazardous voltage levels are present within the UPS. It should be opened utterly by qualified overhaul personnel.
  • The UPS must be appropriately grounded.
  • The battery supplied with the UPS contains microscopic quantity of toxic materials.
  • Under no circumstances operate the UPS if the ambient temperature and relative humidity are higher than the levels specified in the citations.
  • Never burn the battery (risk of explosion).
  • Do not endeavour to open the battery (the electrolyte is dangerous for the eyes and skin).
  • Act in accordance with all applicable regulations for the disposal of the battery.
  • Wait five minutes before opening the UPS to allow the capacitors to discharge.
  • There will be high leakage current; the grounding conductor must be connected first.
  • The product must be installed on a non-inflammable surface (e.g. concrete).
  • The battery replacement must be carried out by qualified personnel.
Product safety

A safeguard circuit breaker must be installed upstream and downstream, and be without problems accessible.
  • Under no circumstances install the UPS near liquids or in an excessively damp environment.
  • Never let a liquid or foreign body penetrate inside the UPS.
  • Never obstruct the ventilation grates of the UPS.
  • Never expose the UPS to direct sunlight or a source of heat.
  • When replacing battery cells, use the identical type and number of cells.
Special precautions

The UPS connection instructions enclosed in the manual must be followed in the indicated order. Ensure that the indications on the rating plate match up to your AC-power system and to the actual electrical utilization of all the equipment to be connected to the UPS.
  • If the UPS must be stored prior to installation, storage must be in a dry place. The admissible storage temperature range is -25°C to +45°C.
  • If the UPS remains de-energized for a long period, It is recommend to energize the UPS for a period of 24 hours, as a minimum each three months. This charges the battery, thus avoiding possible irreversible damage.
  • The UPS is designed for typical climatic and environmental operating conditions concerning the altitude, ambient operating temperature, relative humidity and ambient transport and storage conditions.
  • Using the UPS within the given limits warrantees its operation, but may affect the service life of certain components, particularly that of the battery and its autonomy.
  • The maximum storage time of the UPS is limited due to the need to recharge the battery.
  • Unusual operating conditions may justify unique design or protection measures such as destructive smoke, dust, abrasive dust, humidity, vapour and radiant heat from other sources.
Installation and testing

The mechanism and testing of the UPS is significant to its appropriate operation. The UPS shall be installed with all essential features.  Features such as, indicators, alarms, control devices, and protective devices are installed to aid in the safe operation of the unit.  Power and control modules such as meters, indication lamps, control switches, push buttons, and potentiometers are usually located in a close proximity cabinet.  Batteries are typically installed on battery shelves.  The design of battery racks varies based on the vacant space and number of batteries.

Location

The UPS shall be installed on a level surface with adequate clearance to allow for ventilation and access to safeguarding panels.  Static UPSs require environments with a controlled environment where the THD Levels (temperature, humidity, and dust) are carefully maintained. The batteries of the UPS require ventilation of the room to avert hydrogen buildup.

Protection

The power distribution system of the UPS is designed to provide isolation of critical load and, short circuit protection from sources of surges & harmonics. This can be attained by using circuit breakers, fuses and panel boards. The grounding of the UPS system guarantees the safety of the operating personnel.

Testing and Activation

Testing and activation shall be performed to make sure the component's operation once energized. Testing traces on test forms should be kept for assessment to later regular maintenance tests.  The potential breakdowns of the equipment drawn out from the test results should be discussed and corrective action must be implemented.

Maintenance

There two main maintenances required for the UPS that consists if preventive and remedial maintenance. The Preventive maintenance consists of planned list of activities. Performing these preventive activities keeps the UPS in healthy condition and helps to prevent breakdowns. On the other hand; The Corrective maintenance is performed as a result of a breakdown. This reactive maintenance troubleshoots and gets the unit working over again.The fundamental static UPS system consists of a rectifier-charger, inverter, static switch, and battery.

The rectifier provides the DC power to the inverter, receives the normal AC power supply and charges the battery. In order to provide the intended loads, the inverter converts the DC power to AC power. Upon failure of the main AC power source or the rectifier, the DC power will normally be provided from the rectifier and from the battery.  The inverter will supply the loads under normal conditions.  In the event of the malfunction of the inverter, the static switch transfers the load to an alternate ac source.

Normal Operation

The rectifier converts the AC input power to DC power with adjusted voltages during normal operation. In order to charge the battery while supplying DC power to the inverter, the output of the rectifier voltage is generally set at the battery float voltage. The rectifier output voltage is periodically set at the battery balance voltage to maintain the battery capacity. To reduce the current ripple content, the DC filter is provided for smoothing out the rectifier output current.  The battery acts as a capacitor and in combination with the filter, smoothes out the output voltage and minimizes the DC voltage ripple content. The inverter converts the DC power to AC power with regulated voltage and frequency.

Normal Power Loss

The battery maintains the DC supply to the inverter upon normal power loss. The DC power supply to the inverter can be maintained by the battery until the power restoration of AC supply or end of the battery life cycle. Only under this condition, the inverter continues to supply the connected loads without

any disruption. This sequence of operation will carry on until the system is shutdown only if the battery reaches the discharged state before the output of the charger is restored. A system shutdown may be initiated manually or without human intervention by a dc under voltage sensing device.

Power Restoration

The first thing is that the battery will discharge subsequent to power restoration of the AC supply and the rectifier output voltage is placed at the equal or balanced voltage in order to boost the battery. This mechanism can be performed either manually or without human intervention.

The battery charger returns to the floating method at the end of the battery recharging period and the system returns to normal procedure.

Bypass mode

The static UPS systems may have three bypass switching preparations:  the UPS static switches (SS), the UPS static switch circuit breaker (SS-CB), and the maintenance circuit breaker.

Note

An annual thermography test is to be carried out on all electrical panels and rotating machinery once a year in March. This does not necessitate a shutdown and can be carried out whilst the equipment is on line

About the Author
  • Mohammad Umair Qureshi Profession:Electrical Engineer Location:Doha,QATAR I have been employed as an Electrical Engineer at ADIA.



Thank you for your coming here in UPS Today blog, we hope the article above will help you to know more about your interruptable Power Supply and other. Please comment here when you want to share and other. Thank you.


Nama Anda
New Johny WussUpdated: 12:30 AM

1 comments:

Highlight Article

Uninterruptible Power Supply (UPS): Definition, Typically Used, and Technology

UPSToday . - Uninterruptible Power Supply (UPS) that shortly called with UPS now to be something that very useful in this time. Hardware su...

Recent Articles

Popular Articles

CB